Excellent cycle life in repeated charge/ discharge conditions
DoD 80%>3000 cycles; Service life>10 years
Suitable for Ni-Cd battery replacement
Consistency and Reliablity, Nonflammable and Nonexplosive
|
TMK Model |
Volt |
Capacity |
Dimensions |
Standard Charge |
Rapid Charge |
Wt. |
||||
|
App. |
||||||||||
|
Typical |
Min. |
H |
Dia. |
mA |
h |
mA |
min |
g |
||
|
mAh |
mAh |
mm |
mm |
|||||||
|
D800L |
1.2 |
8000 |
7500 |
60.0±0.5 |
32.0+0.6 |
800 |
16 |
4000 |
140 |
155 |
|
D900L |
1.2 |
9000 |
8500 |
60.0±0.5 |
32.0+0.6 |
900 |
15 |
4500 |
140 |
165 |
|
F1200L |
1.2 |
12000 |
11500 |
89.0±0.5 |
32.0+0.6 |
1200 |
15 |
2400 |
140 |
230 |
|
F1300L |
1.2 |
13000 |
12500 |
89.0±0.5 |
32.0+0.6 |
1300 |
15 |
2600 |
140 |
245 |
Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Power tools, electric forklifts, flashlights, medical care, solar lighting

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Emergency lighting, exit signs, solar lighting, flashlights, torches, others

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Emergency exit lights, power tools, flashlights, medical supplies

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar street lamps, emergency lighting, robots, safety, medical equipment

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Emergency exit sign, electric tool, medical treatment, solar lighting

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Emergency lighting, exit signs, solar lighting, flashlights, torches, others

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Emergency lights, power tools, Flashlights,

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Electric tools; Flashlights; medical treatment

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Power system, solar energy storage system

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar lighting, electric tool , medical treatment , solar energy storage systems

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar lighting, electric tool , medical treatment , solar energy storage systems

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar lighting, electric tool , medical treatment , solar energy storage systems

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar lighting, electric tool , medical treatment , solar energy storage systems

Cycle Life : 1000~3000
Charging Temperature : -20~+50℃
Standard Charging Current : 0.1C~0.5C
Max discharge current : 2C
serve : OEM/ODM
application area : Solar lighting, electric tool , medical treatment , solar energy storage systems