Continuous discharge 5-15C, Instant Max 30C.
Excellent consistency and reliability nonflammable and nonexplosive.
Cycle Life>500 with 1C charge & 5C discharge.
Low internal resistance enable high-rete discharging and guarantee stable discharge voltage.
|
TMK Model |
Volt |
Capacity |
Dimensions |
Standard Charge |
Rapid Charge |
Wt. |
||||
|
App. |
||||||||||
|
Rated |
Min. |
H |
Dia. |
mA |
h |
mA |
min |
g |
||
|
mAh |
mAh |
mm |
mm |
|||||||
|
AA120H |
1.2 |
1200 |
1150 |
48.5±0.5 |
13.9+0.5 |
120 |
16 |
1200 |
72 |
24 |
|
AA140H |
1.2 |
1400 |
1350 |
49.0±0.5 |
14.0+0.5 |
140 |
16 |
1400 |
72 |
27 |
|
4/5SC200H |
1.2 |
2000 |
1950 |
33.5±0.5 |
22.0+0.6 |
200 |
16 |
2000 |
72 |
42 |
|
4/5SC220H |
1.2 |
2200 |
2100 |
33.5±0.5 |
22.0+0.6 |
220 |
16 |
2200 |
72 |
45 |
|
SC150H |
1.2 |
1500 |
1500 |
42.5±0.5 |
22.0+0.6 |
150 |
16 |
1500 |
72 |
41 |
|
SC180H |
1.2 |
1800 |
1800 |
42.5±0.5 |
22.0+0.6 |
180 |
16 |
1800 |
72 |
46 |
|
SC200H |
1.2 |
2000 |
2000 |
42.5±0.5 |
22.0+0.6 |
200 |
16 |
2000 |
72 |
48 |
|
SC250H |
1.2 |
2500 |
2450 |
42.5±0.5 |
22.0+0.6 |
250 |
16 |
2500 |
72 |
55 |
|
SC300H |
1.2 |
3000 |
2900 |
42.5±0.5 |
22.2+0.6 |
300 |
16 |
3000 |
72 |
58 |
|
D800H |
1.2 |
8000 |
7800 |
60.0±0.5 |
32.0+0.6 |
800 |
14 |
4000 |
140 |
178 |
|
F1000H |
1.2 |
10000 |
9500 |
90.0±0.5 |
32.0+0.6 |
1000 |
14 |
5000 |
140 |
230 |
|
F1200H |
1.2 |
12000 |
11500 |
90.0±0.5 |
32.0+0.6 |
1200 |
14 |
6000 |
140 |
238 |
Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Power tools, electric forklifts, flashlights, medical care

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Solar street lamps, emergency lighting, robots, safety, medical equipment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Emergency lighting, exit signs, solar lighting, flashlights, torches, others

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Emergency exit lights, power tools, flashlights, medical supplies

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Industrial applications, emergency lighting, exit signs, solar lighting and solar energy storage systems, medical, power tools, solar lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Industrial applications, emergency lighting, exit signs, solar lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, medical supplies, flashlights, solar energy storage systems, power systems

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, medical treatment, solar energy storage systems, emergency lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, portable cleaners, medical treatment, solar lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : solar lighting, emergency lighting , solar energy storage systems, medical treatment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, solar energy storage systems, medical treatment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, medical treatment, emergency lighting, solar lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Solar lamps, emergency lights, exit signs, flashlights, torches, others

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Toys, power tools, flashlights, solar energy storage systems

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Fishing lamp, medical equipment, electric tool , emergency lighting, solar lighting

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : Solar-powered lighting for emergency use, exit signs, flashlights, torches, others

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : solar lighting, emergency lighting , solar energy storage systems, medical treatment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : solar lighting, emergency lighting , solar energy storage systems, medical treatment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : solar lighting, emergency lighting , solar energy storage systems, medical treatment

Cycle Life : 500
Charging Temperature : -20~+50℃
Standard Charging Current : 0.2C~1C
Max discharge current : 10-15C
serve : OEM/ODM
application area : solar lighting, emergency lighting , solar energy storage systems, medical treatment